![]() |
![]() |
![]() |
||||
| |
|
Home Page: http://www.wheeler-con.com E-Mail: info@wheeler-con.com Info Request: Click here for form |
||||
STEEL RECREATION BRIDGES |
||||
|
|
Notes and Instructions to
Specification Writer: These specifications shall be regarded as minimum standards for design and construction. Substructures are not included in this item. The truss type shall be (Choose One): as determined by the Bridge Manufacturer; parallel chord with vertical ends; parallel chord with sloped ends; bow truss (bowstring truss, truss arch); bowstring arch (tied arch, with vertical hangers only); lenticular; other with a web member style (Choose One): of Pratt; of Howe; of Vierendeel; of Warren, (with verticals / without verticals / with or without verticals); of crossed diagonals, (with verticals / without verticals / with or without verticals); as determined by the Bridge Manufacturer; as depicted in the Plans. Pratt or Howe style trusses with an odd number of bays shall have crossed diagonals in the middle bay. Any crossed diagonals shall be of equal dimension. Unless specified otherwise, multiple spans or bridges within a project shall have a consistent style, multi-span bridges shall maintain a constant depth, and any bridge depiction shown in the Plans is conceptual only. Overhead (portal) bracing is (Choose One): prohibited; required; allowed. Span Length(s): (Note: Option 1 should be used when abutments are fully designed in advance and their position cannot be slightly adjusted. Typical trail bridges are available up to 200 to 250 feet depending on deck type and width; costs begin to climb substantially for spans above these limits and should only be considered for landmark class bridges or when piers are essentially impossible; true arch and bowstring arch bridges are available at considerably longer spans. For vehicular bridges, preliminary designs are recommended when deck area exceeds 2500 ft2. Skew angles are virtually unlimited, however it is generally less expensive to increase the bridge length such that ends are square. Horizontal curvature is possible, but preliminary designs are required.) (Note: 1% is generally recommended as a minimum for parallel chord bridges unless a flatter profile grade must be followed. With arches, covered bridges, and where a nearly flat appearance is otherwise desired, 0.2% is recommended. When a bridge is part of an accessible route per ADA, consider that 1.25% camber translates to a 5% instantaneous slope at bridge ends. The owner is generally responsible to make sure ADA requirements are met. Also consult the AASHTO Guide For the Development of Bicycle Facilities when applicable; this manual states grades greater than 5% are undesirable, and when necessary should be restricted to short sections.) (Note: Without further analysis of lateral stiffness, deck widths should generally not be less than: (Note: This information could instead appear in the Plans. It is recommended the backwall height be roughly 20" min to 30" max for spans 70 ft or less, and roughly 32" min to 96" max for 200 ft+ spans, interpolate. Use the minimum value for arch type bridges. Use roughly 20" for bridges of any span with overhead bracing. Structure depth (top of deck to low steel) is roughly equal to backwall height minus 4" to 6". Further fine-tuning is possible at the preliminary stage, call to discuss. Additional height adds economy which must be balanced with abutment cost and under-clearance requirements, also consider that a higher backwall will translate to a shorter span for a given profile grade. It is recommended that the abutment bridge seat width be no less than 16" for all bridges, 18" for 150 ft + spans, and 20" for 200 ft + spans. Double the above number for pier width. Abutment and pier length should generally be at least equal to clear bridge width plus 24" for spans 50 feet or less, and clear width plus 50" for 200 ft+ spans, interpolate.) (Note: For trail and foot bridges, when a specific agency designated vehicle does not exist, it is recommended that the H5 (5 ton) vehicle be designated for bridges 8 ft or more in width unless access is physically prevented. Other AASHTO vehicles can be specified if required. The H# corresponds to the total vehicle weight in tons. Bridges designated to serve legal highway loads as previously specified shall be designed for no less than the AASHTO specified truck, tandem, and lane loads (HS20). When consideration of snow load is required, specify the load and whether or not the snow load must be considered simultaneously with any other transient loads. When the bridge superstructure (or piers when applicable) will be at all submerged during a 100 year flood event, all pertinent hydraulic information will be required if the Bridge Manufacturer is to design for this situation. Of particular concern are water surface elevation, velocity, and debris or ice potential. Stream flow acting against a debris pile is the most likely cause of a superstructure washing out (not considering substructure failures). The Project Engineer or another familiar with the site must specify the dimensions of a design debris pile, any increase in water surface elevation due to debris, and thickness and strength of ice at breakup when applicable.) (Note: Level one is consistent with the current AASHTO provisions which are generally considered adequate for lightly used trail bridges. Level two is consistent with AISC recommendations for outdoor foot bridges and will provide more consistent designs (max acceleration will be the same regardless of span length), and does not affect spans over roughly 130 feet, but will affect shorter span bridges; acceleration by level one design can be as much as triple that of level two. Level three is consistent with AISC recommendations for indoor bridges and will reduce vibrations considerably; level three may be considered necessary for heavily used outdoor pedestrian bridges, particularly those where people may stand in stationary positions for any length of time. Level four should only be considered for use with very specialized structures when it is intended that people may sit on the structure. As a point of reference, level three criteria are similar to AISC recommendations for shopping malls, and level four to offices and residences. To meet level three or four provisions, heavier deck types such as asphalt or concrete should be allowed (not necessarily required), and spans exceeding 120 ft (level three) or 70 ft (level four) should be avoided without more in-depth analysis. Be aware that the above provisions allow for a level one or two design with a natural frequency of less than 3 Hz (in accordance with AASHTO), which greatly increases the chance for resonance due to normal human activity and is discouraged by AISC; however, allowing frequencies of less than 3 Hz enables long span prefabricated bridges to be a practical possibility, and complaints are typically rare.) Deflection of the truss due to uniform live load shall be limited to L/500. The load may be reduced based on loaded area to no less than 65 psf. Deflections in longitudinal deck members due to uniform live load shall be limited to L/500. No other service deflection limits need be considered. (Note: Deflection and vibration limits are always owner defined and may be changed (or deleted) at the owners discretion, call to discuss the effect on cost. For vehicular bridges, the traditional AASHTO deflection criteria may be imposed at the owners discretion and then must be clearly specified as to how and where the limit is applied. AASHTO no longer encourages use of those deflection limits. When trucks and pedestrians may be on a bridge at the same time, such as with cantilevered sidewalks, special consideration is required.) Steel material shall be corrosion resistant high-strength low-alloy material meeting ASTM A242, A588, A606, or A847 with a minimum corrosion index of 5.8 per ASTM G101. Minimum thickness of tubular steel members (not including railings) shall be (Choose One): 3/16”; 1/4” for primary truss members and 3/16" elsewhere"; 1/4"; other. Where water collection inside of structural tubing is possible during construction or service, weep holes shall be provided at low points. All steel shall be (Choose One): unpainted and self-weathering. All exposed surfaces, defined as those surfaces seen from the deck and from along side the structure, shall be blast cleaned in accordance with Steel Structures Painting Council Surface Preparation Specifications No. 7, latest edition, (SSPC-SP7) Brush Off Blast Cleaning. painted. The paint system shall be a three coat system suitable for the intended use as recommended by the paint manufacturer and approved by the Owner. Application shall be in accordance with the recommendations of the paint manufacturer. Applicator shall be certified by the paint manufacturer for the approved paint system. Color of the finish coat shall be determined by the Owner. All painted surfaces shall be blast cleaned in accordance with Steel Structures Painting Council Surface Preparation Specifications No. 7, latest edition, (SSPC-SP10) Near White Blast Cleaning. Painted bridges shall be configured such that all surfaces and connections are either fully sealed or allow access for adequate paint coverage. Sealing shall be accomplished by welding except that long continuous seams may be sealed with caulk prior to painting. All surfaces shall be painted, with the exception of expansion joint cover plates, teflon surfaces, bolted connections, and faying surfaces. Touch up paint shall be provided to paint outer surfaces of bolted splices and areas of damaged paint. Splices not immediately at or adjacent to panel points shall be designed for 100% of the member bending moment capacity for primary compression members, and 75% for bracing members or tension members subject to load reversal, including slip resistance, and slip resistance shall further meet the same AASHTO required strength as with other failure modes. Splices for truss members, bracing, and floor beams, when used, shall be made with ASTM A325 or A490 high strength bolts. Type 3 bolts shall be used when the truss is required to be of weathering steel. Other splices shall be made with the above mentioned material or ASTM A307. When the ends of the truss are not vertical, railings (Choose One): shall; need not extend full height to the end of the bridge. Bridges designated for use by pedestrians, bicycles, or snowmobiles shall be equipped with 5" minimum steel toe rails, located no more than 2" clear above the bridge deck. Bridges designated as vehicular bridges shall be equipped with traffic rails conforming to AASHTO Test Level 1 (TL-1). Rub rails, handrails, and toe rails shall be designed per AASHTO as horizontal rails. When the bottom of the top chord is higher than 54" and there is no rub rail or hand rail, a rail designed per AASHTO as a horizontal rail shall be provided no higher than 54". When bridge structural members support or serve as railing members, the bridge shall be designed for the simultaneous application of rail load plus dead load plus 50% of live load. All rails shall be of a smooth, continuous nature that prevents snagging and scraping. The rub rail shall be ___ inch minimum nominal height, centered at ___ inches plus or minus 2" above the initial and future deck surface. (Fill in rail size and location) Actual outside diameter shall be 1-1/4" minimum, 2” maximum. The top of the handrail shall be 36" plus or minus 2" above the initial and future deck surface. The handrail shall have a minimum 1-1/2" knuckle space, shall not rotate within fittings. The bridge deck shall be (Choose One): transverse Douglas Fir planks. Planks shall be nominal 3” (minimum) Coastal Region Douglas Fir, graded as Select Structural as per the Western Wood Products Association (WWPA) or the West Coast Lumber Inspection Bureau (WCLIB). Treatment shall be as per the American Wood Preservers Association (AWPA) Standard P5. The preservative utilized shall be Ammoniacal Copper Zinc Arsenate (ACZA) to a total absorption of 0.40 pounds per cubic foot of wood. Planks shall be placed tight together with no gaps. To resist warping forces, deck tie-down systems shall be designed to resist an uplift force of 500 lbs per plank per tie-down location, assuming wet service conditions. Deck tie-downs shall be provided at plank ends and intermediate points as required such that tie-down spacing does not exceed actual plank thickness multiplied by 50. Edge tie-downs shall be made with a continuous steel angle member above the planks. A wear course (Choose One): of 2” (treated/untreated) S4S Southern Pine No. 2 timber planking, placed (longitudinally / at 45 degrees), shall be included; will be installed at a later time by others; is not anticipated now or in the future; other. transverse Ipe wood planks. Ipe wood (Tabebuia spp.-lapacho group) shall be nominal 2” (minimum), all heartwood (no sapwood), clear (no knots), straight grained, with no worm holes, shall be surfaced four sides and eased four edges, and be air dried to no more than 20% moisture content prior to installation. Planks shall be placed tight together with no gaps. To resist warping forces, deck tie-down systems shall be designed to resist an uplift force of 500 lbs per plank per tie-down location, assuming wet service conditions. Deck tie-downs shall be provided at plank ends and intermediate points as required such that tie-down spacing does not exceed actual plank thickness multiplied by 50. Edge tie-downs shall be made with a continuous steel angle member above the planks. Material shall be untreated. Ends of members shall be sealed with a clear aqueous wax water sealer. An oil based surface sealer that will maintain the natural color of the wood (Choose One): is; is not required. Sealing products shall be suitable for the intended application and applied in accordance with the manufacturers recommendations. dowel-laminated panel-lam. Panel-lams shall be nominal 4” (minimum) Coastal Region Douglas Fir. Preservative treatment of timber shall be by the pressure process in accordance AWPA Standards and AASHTO Designation M 133. Preservative shall be Copper Naphthenate in AWPA P9 Type A Hydrocarbon Solvent. Unless otherwise directed by the Owner the material shall be graded prior to treatment. Material shall be accepted after treatment on the basis of its condition prior to treatment, on the basis of inspection of the treatment procedure substantiated by plant records, on the condition of the material after treatment and on absorption, penetration and visual inspection. So far as practicable all adazing, boring, chamfering, framing, gaining, mortising, surfacing and general framing, etc., shall be done prior to treatment. If cut after treatment, coat cut surfaces according to AWPA M4. All Douglas Fir and other species that are difficult to penetrate shall be incised prior to treatment. Panel-lams shall be shop fabricated with ring-shank dowels in a press capable of simultaneously driving all the dowels with equal force. Panels shall be interconnected with shiplap joints. Panels placed longitudinally shall be continuous over as many floor beams as is practical. A wear course (Choose One): of 2” (treated/untreated) S4S Southern Pine No. 2 timber planking, placed (transversely / longitudinally / at 45 degrees), shall be included; of 2” asphalt shall be included; will be installed at a later time by others; is not anticipated now or in the future; other. When there will be an asphalt wear course, the deck shall have edge strips to contain the wear course. normal weight reinforced concrete. The Bridge Manufacturer shall provide 20 gage (minimum) stay-in-place galvanized metal decking with steel side and end dams. Concrete decks shall be rough broomed transversely. Metal decking shall be secured with fasteners or welds as recommended by the decking manufacturer. Upper and lower layers of longitudinal reinforcement are required. One layer of transverse reinforcement shall be provided when the deck thickness above ribs is less than six inches, and two layers when six inches or greater. Reinforcing bars shall be placed 2" min clear to top surface, and 1" min clear to all other surfaces or forms. Consideration of composite action from the metal form is prohibited. Concrete and reinforcement in troughs may be considered as contributing the strength of the deck when it can be shown this assumption is valid. Metal forms shall be designed for a construction live load of either 20 psf or a 200 lb point load. Dead load deflection due to wet concrete shall be limited to L/180 and 3/4". Bridge slab concrete shall be 4000 psi normal weight concrete. Aspects of concrete work, including but not limited to material properties, mix designs, plant and field quality control, and rebar placement including support and tying, shall be governed by AASHTO unless specified otherwise. Reinforcing bars, when used, shall conform to AASHTO M31, M42, or M53, grade 60. Concrete and asphalt surfaces shall be constructed with a cross-slope of 1% unless camber is at least 1% or longitudinal grade is at least 1%. Nondestructive weld testing is required. Testing will be performed by a qualified ASNT Level II Technician or greater and paid for by the Bridge Manufacturer. All welds are to be 100% visually inspected. Ten percent (10%) of all fillet and partial penetration welds shall be magnetic particle tested. For arch type bridges, 100% of end of top chord to bottom chord connections shall be tested. Full penetration shop welds shall be Ultrasonic tested in accordance with AWS D1.1; Section 6. Base material certifications are to be supplied by the material suppliers. Inspection test results shall be available on request. Wood members shall be attached with carriage bolts. All wood connections shall be made with locking hardware. The Owner will be responsible for tightening loose hardware after initial acceptance. Cover plates shall be provided to cover expansion gaps when pedestrian usage is specified. Cover plates shall fit tight to the top of the abutment backwall without any bridge weight bearing on the backwall. Consider joint size and weight of vehicles regarding plate thickness. Anchors shall be of the drilled type, installed with a chemical adhesive system, except that when design forces exceed the strength of typical chemical systems, cast-in-place anchors may be used. Anchor systems shall be designed and supplied by the Bridge Manufacturer. Anchor bolts shall conform to ASTM A307, A193, or F1554. All hardware (other than type 3 high strength) shall be hot-dip galvanized in accordance with ASTM A153. Expansion bearings shall include teflon or stainless steel sliding surfaces per AASHTO or elastomeric pads. Consideration of dead load rotation is required in all cases. Cementitious non-shrink grout, when applicable, shall meet ASTM C-1107, 7000 psi minimum. Materials not specified shall conform to applicable ASTM or AASHTO specifications. Delivery to the job site will be by trucks by means of good haul roads unless specified otherwise. The Bridge Manufacturer shall provide detailed, written instruction procedures for proper lifting and splicing of bridge components. (Make sure that all italics text has been properly incorporated into the specifications or deleted. Delete all notes) |
![]() Home |
Manufactured By: Wheeler Lumber, LLC |